PULSE EVALUATION SYSTEM D100
Transistor output (D100 with AC/DC switched-mode power supply)
PNP, 24 V DC (± 20%), 200 mA, external supply at terminal 9.
The voltage of the short-circuit protected transistor output is switched to terminal 10 depend-
ing on the selected function. It is not allowed to apply external voltage to terminals 10 and 11.
Unit data
Dimensions: 75 x 55 x 110 (H / W / D), weight: max. 400g
Protection rating housing: IP 40, protection rating terminals: IP 20
Connection: 16 terminals, wire cross section: max: 2.5mm
2
Environmental conditions
Permissible ambient temperature: -20°C ... +60°C in open air
Humidity: max. 75% up to +35°C, non condensing
Air pressure: 75 KPa to 106 KPa
Maximum operating altitude: 2000m above sea level
CE marking
The unit has the CE mark which is necessary for the free exchange of good within Europe. It
shows that the unit meets the requirements according to the accepted general protective pur-
poses. In particular it shows the conformity with the following guidelines:
EMC guideline EMC 89/336/EEC,
stipulated in the standards EN 60947-5-2 annex X
(The user is responsible for the interference suppression of the relay circuit according to the
standard).
Low voltage guideline LV 73/23/EEC,
stipulated in the standard EN61010:1993 + A2:1995
Other requirements, e.g. concerning the EC guideline for machines, are to be considered by
the user in his planned application and are not part of the
certificate of conformity.
Notes on the cULus certification (DD0116 and DD0122)
According to the certification the above-mentioned units correspond to the following technical
data:
Nominal voltage AC/DC:
DD0116: 110...240 V (50...60 Hz)
DD0122: 27...60 V (50...60 Hz)
Tolerance: -20...+10%
Nominal voltage DC:
All above-mentioned units
27 V (typ. 24 V), Tolerance: -20...+10%
Contact rating:
According to cULus classification 6 A (250 V AC), B300, R300
Test conditions:
Housing dimensions for the temperature-rise test 200 x 200 x 150 mm.
Connection terminals:
Up to 2.5 mm 2 ; AWG 14